CTAFH High-efficiency water dust and oil removal precision filter
Product Description
Residual oil measurement-OIL-Check 400
Continuously and accurately measure the residual oil content in the form of steam
ftom 0.001 mg/m'to 2.5 mg/m?. Class 1 compressed ai qualty can be monitored
through alow detection limit of 0.001mg/m'(SO 8573).
Particle counter PC 400
The high-precision optical particle counter PC 400 can measure particles as low as
0.1 μ m in size. so it is sultable for monitoring the qualy of compressed air at level 1
(18O 8573).
Residual humidity - dew point sensor FA 510
FA510 can measure the pressure dew point up to-80°Ctd. At this time, continuous
measurement can also ensure that the alarm will be tiggered immediately when
the compressed air dryer fails.
Technical parameter
| ISO 8573-1:2010(grade) | Solld parlicles | Woter | |||
| Maximum number of particles per m' | |||||
| 0.1-0.5μm | 0.5-1μm | 4-Gun | mg/m | ||
| 0 | Aacoiding to the regulatiors of me squc | ||||
| 1 | <=20,000 | <=400 | <=10 | <=-70℃ | 0.01 |
| 2 | <=400,000 | <=6,000 | <=100 | <=-40℃ | 0.1 |
| 3 | - | <=90,000 | <=1,000 | <=-20℃ | 1 |
| 4 | - | - | <=10,000 | <=+3℃ | 5 |
| 5 | - | - | <=100.000 | <=+7C | - |
| 6 | - | - | - | <=+10℃ | - |
| 7 | - | - | - | - | - |
| 8 | - | - | - | - | - |
| 9 | - | - | - | - | - |
| X | - | - | - | - | - |
ACF Series Precision Filter Selection Table
| Filter model | Connecton so | tatwe | low | |||
| C.LA,FH | Rc | Amm | B mm | Cmm | w min | |
| YF-*-015 | 1/2"、3/4" | 100 | 200 | 235 | 1.5 | MS-015* |
| YF-*-025 | 3/4'、1' | 100 | 240 | 275 | 2.5 | MS-025* |
| YF-*-038 | 1'、1-1/2" | 125 | 290 | 335 | 3.8 | MS-038* |
| YF-*-060 | 1-1/2* | 125 | 420 | 465 | 6.0 | MS-060* |
| YF-*-085 | 1-1/2* | 125 | 420 | 465 | 8.5 | MS-085* |
| y*.120 | 2" | 152 | 529 | 590 | 12.3 | MS-120* |
| YF-*-150 | 2" | 152 | 569 | 630 | 15.2 | MS-150* |
| YF-*-210 | 2'、2-1/2* | 180 | 590 | 688 | 21.8 | MS-210* |
| YF-*-300 | 2-1/2'、3" | 208 | 628 | 707 | 30.5 | MS-300* |
| YF-*-400 | 3" | 208 | 718 | 897 | 40.2 | MS-400* |
Filter element filtration accuracy and effectiveness
Working pressure correction factor
When the pressure is not 7kgf/cm',the fiow rate of the selected filter should fist know the maximum flow at the fiter inlet and then divlde by the comection factor comesponding to the minimum pressure of the titer inlet to select the appropriate filter size.
| Intake pressure Mpa | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1 | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.6 |
| C1 | 0.76 | 0.85 | 0.93 | 1 | 1.07 | 1.13 | 1.19 | 1.25 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |